Saturday, May 19, 2012
Scotgrid in the Big Apple for CHEP
We are attending the WLCG and CHEP in New York this week. There will be regular updating of the blog with details of the talks and papers we are attending.
Monday, May 07, 2012
Stockholm LHCONE Meeting
Kristall in the Sergels Torg Stockholm
We were in attendance at the LHCONE meeting at KTH in Stockholm last week. The purpose of this collaboration is to investigate the efficient use of networks globally for LHC research. As usual it was an excellent meeting where the technical mechanisms for current and future network deployments were discussed and considered.
The agenda can be found here. Some of the highlights of the meeting included an excellent presentation by Erwin Laure on the Swedish and Scandinavian Super Computing and Grid computing infrastructure, Joe Mambretti's presentation on the GLORIAD global research network, Mike O'Connor's discussion on the technical configurations required to avoid asymmetric routing issues between the LHCONE and the current production networks and Domenico Vicinanza's presentation on Perfsonar MDM.
In addition to these presentations technical discussions surrounding various technologies surrounding bandwidth reservation, ultra high speed networking and Open Flow technologies were held. As these discussions develop through the network architecture groups we will keep you up to date.
Also, the weather in Stockholm was exceptional and the KTH Campus is worth a visit for its architecture alone. I would like to thank our hosts and all the other attendees for making this such an enjoyable and informative couple of days.
KTH Campus Stockholm
Sunday, May 06, 2012
Preparing for IPv6
Generally, we don't repost news items on the blog but this BBC article gives a good indication of the changes underway globally for implementing IPv6.
currently the Glasgow Scotgrid test cluster is being revamped post our last spending cycle and we are embarking on a full test programme of IPv6 specifically around running Grid services.
As this work progresses we will regularly update the blog.
Thursday, May 03, 2012
GridPP At The Top Of Europe
This news article appeared on the GridPP website and is worth reposting to our blog as it gives an overview of the collaborations efforts to date within the WLCG and with the Non High Energy Physics (HEP) communities.
GridPP At The Top Of Europe
GridPP At The Top Of Europe
Tuesday, April 17, 2012
One XOS, Great Big Purple Packet Eater. Sure looks good to me.
So we haven't been blogging a great deal since December and for good reason. We found ourselves in the exciting position of being given additional funding to enhance our network capability and also we had additional equipment to install into the cluster.
First things first however, as you may have read we have had no end of issues with the older network equipment. We had a multi-vendor environment which, while adequate for 800 analysis jobs and 1200 production jobs, wasn't quite up to cutting the mustard as we couldn't expand from there.
The main reason was the 20 Gig link between the two computing rooms which was having real capacity issues. Also, add in issues between the Dell and Nortel LAG and associated back flow problems, sprinkled with a buffer memory issue on the 5510s and you get the picture. In addition to this we were running out of 10 Gig ports and therefore couldn't get much bigger without some investment.
Therefore, the grant award was a welcome attempt to fix this issue. After going to tender we decided upon equipment from Extreme Networks. The proposed solution allowed for a vast 160 Gigabit interconnect between the rooms broken into two resilient link bundles in the Core and an 80 Gigabit Edge layer. In addition to this connection we also installed a 32 core OM4 grade fiber optic network for the cluster which will carry us into the realms of 100 Gigabit connections, when it becomes available and cheap enough to deploy sensibly.
We now have 40 x 40 gigabit port, 208 x 10 gigabit ports and 576 1 x Gigabit ports available for the Cluster.
The new deployment utilises X670s in the Core and X460s at the Edge.
The magic of the new Extreme Network is that it uses EAPS, so bye bye Spanning Tree and good riddance as well as MLAG which allows us to load share traffic across the two rooms so having 10 Gigabit connections for disk servers in one room is no longer an issue.
Then it got a bit better. Due to the Extreme OS we can now write scripts to handle events within the network which ties in with the longer term plan for a Cluster Expert System (ARCTURUS) which we are currently designing for test deployment. More on this after August.
Finally, it even comes with its own event monitoring software, Ridgeline which gives a GUI interface to the whole deployment.
We stripped out the old network installed the new one and after some initial problems with the configuration, which were fixed in a most awesome fashion by Extreme got the new one up and running. What we can say is that the network isn't a problem anymore, at all.
This has allowed us to start to concentrate upon other issues within the Cluster and look at the finalised deployment of the IPV6 test cluster which has benefited in terms of hardware from the new network install. Again, more on this soon.
Right, so now to the rest of the upgrade we have also extended our cold isle enclosure to 12 racks, have a secondary 10 Gig link onto the Campus being installed and have a UPS. In Addition to this we refreshed our storage using Dell R510s and M1200s as well as buying 5 Interlagos boxes to augment the worker node deployment.
We also invested in an experimental user access system with wi-fi and will be trying this out in the test cluster to see if a wi-fi mesh environment can support a limited number of grid jobs. As you do.
In addition to this we improved connectivity for the research community in PPE at Glasgow and across the Campus as a whole, with part of the award being used to deliver the resilient second link and associated switching fabrics.
It hasn't been the most straight forward process as the decommissioning and deployment work was complex and very time consuming in an attempt to keep the cluster up and running as long as possible and to minimise down times.
We didn't quite manage this as well as expected due to the configuration issues on the new network but we have now upgraded the entire network and have removed multiple older servers from the cluster to allow us to enhance the entire batch system for the next 24 - 48 months.
As we continue to implement additional upgrades to the cluster we will keep you informed.
For now it is back to the computer rooms.
First things first however, as you may have read we have had no end of issues with the older network equipment. We had a multi-vendor environment which, while adequate for 800 analysis jobs and 1200 production jobs, wasn't quite up to cutting the mustard as we couldn't expand from there.
The main reason was the 20 Gig link between the two computing rooms which was having real capacity issues. Also, add in issues between the Dell and Nortel LAG and associated back flow problems, sprinkled with a buffer memory issue on the 5510s and you get the picture. In addition to this we were running out of 10 Gig ports and therefore couldn't get much bigger without some investment.
Therefore, the grant award was a welcome attempt to fix this issue. After going to tender we decided upon equipment from Extreme Networks. The proposed solution allowed for a vast 160 Gigabit interconnect between the rooms broken into two resilient link bundles in the Core and an 80 Gigabit Edge layer. In addition to this connection we also installed a 32 core OM4 grade fiber optic network for the cluster which will carry us into the realms of 100 Gigabit connections, when it becomes available and cheap enough to deploy sensibly.
We now have 40 x 40 gigabit port, 208 x 10 gigabit ports and 576 1 x Gigabit ports available for the Cluster.
There is quick and clever and here it is
The new deployment utilises X670s in the Core and X460s at the Edge.
The magic of the new Extreme Network is that it uses EAPS, so bye bye Spanning Tree and good riddance as well as MLAG which allows us to load share traffic across the two rooms so having 10 Gigabit connections for disk servers in one room is no longer an issue.
Then it got a bit better. Due to the Extreme OS we can now write scripts to handle events within the network which ties in with the longer term plan for a Cluster Expert System (ARCTURUS) which we are currently designing for test deployment. More on this after August.
Finally, it even comes with its own event monitoring software, Ridgeline which gives a GUI interface to the whole deployment.
We stripped out the old network installed the new one and after some initial problems with the configuration, which were fixed in a most awesome fashion by Extreme got the new one up and running. What we can say is that the network isn't a problem anymore, at all.
This has allowed us to start to concentrate upon other issues within the Cluster and look at the finalised deployment of the IPV6 test cluster which has benefited in terms of hardware from the new network install. Again, more on this soon.
Right, so now to the rest of the upgrade we have also extended our cold isle enclosure to 12 racks, have a secondary 10 Gig link onto the Campus being installed and have a UPS. In Addition to this we refreshed our storage using Dell R510s and M1200s as well as buying 5 Interlagos boxes to augment the worker node deployment.
The TARDIS just keeps growing
We also invested in an experimental user access system with wi-fi and will be trying this out in the test cluster to see if a wi-fi mesh environment can support a limited number of grid jobs. As you do.
In addition to this we improved connectivity for the research community in PPE at Glasgow and across the Campus as a whole, with part of the award being used to deliver the resilient second link and associated switching fabrics.
It hasn't been the most straight forward process as the decommissioning and deployment work was complex and very time consuming in an attempt to keep the cluster up and running as long as possible and to minimise down times.
We didn't quite manage this as well as expected due to the configuration issues on the new network but we have now upgraded the entire network and have removed multiple older servers from the cluster to allow us to enhance the entire batch system for the next 24 - 48 months.
As we continue to implement additional upgrades to the cluster we will keep you informed.
For now it is back to the computer rooms.
Monday, February 27, 2012
LSC files and emailAddress redux
This post involves a very complicated journey to get to a simple place.
The fundamental problem is around the catchy titled OID 1.2.840.113549.1.9.1
No, wait, let me take a step back. On the Grid, we use certificates for authentication. An X509 certificate is, as with most certificates, a signed set of assertions, and a public key. As with the rest of the X500 standards, it's native language is something called ASN.1 (Abstract Syntax Notation 1) (aka X208, and the later revision X680), held in files encoded by the DER (Distinguished Encoding Rules).
The fundamental takeaway from that tech-dump is that X509 certificates are not in plain text, and there are multiple standards required in order to understand their contents.
So when someone says their certificate Distinguished Name is '/O=SomeUni/OU=SomeDept/L=group/CN=JohnSmith' ... that's not quite accurate. What they really mean is that there certificate DN is some set of objects that can be unambiguously matched to that ASCII text.
That happens because there are universally agreed mappings between the actually stored OID and the text representation of them (e.g. CN is OID 2.5.4.3).
Unfortunately, the agreement breaks down a bit for the emailAddress field; with some software mapping it to Email, and others to emailAddress. By the PKCS#9 standard, one could argue that it should be emailAddress - but that doesn't help us get software working.
Fortunatly, all of this is not a problem unless we want to store certificate DN's in ASCII, _and_ want to have email addresses in the DN.
Yeah, you can see where this is going, can't you?
In the UK, Jens has been working to allow us to not have them in DN's. However, in the short term, they are present.
One particular case where ASCII representations of the DN are used is in LSC files - which are used to authenticate VOMS servers. What happens is if the VOMS server DN matches the DN in the LSC file, and the cert was signed by the CA DN in the LSC file, _and_ the certificate chain is signed by a trusted root, then it's valid. This process means that we don't need to distribute lots of VOMS server certs, just the root CA's, and a small note (that shouldn't change over renewals) of the server DN.
I've been tidying up our ARC install here, and during the process managed to break things. Not unusual for me, (one of the reasons I avoid tiding at all costs!), but this one was quirky. I'd put the vomsdir under CFEngine control, so that it was sync'd with all the other servers, and suddenly it stopped accepting the scotgrid VO.
Root cause, as if you can't guess by now, LSC file, and the emailAddress. Looks like the gLite stack expects it one way, and ARC the other. Of course, by the time you read this, that's probably been fixed somewhere, but not in the version we had installed.
It turns out that there's one trick in LSC files that saves this case. Let me put the LSC file in here:
The 'NEXT CHAIN' line lets one put multiple entries in the file. However, it appears that ARC isn't reading multiple, only the first one. So, in this case, I put the ARC friendly one first, so it matches fine - and the gLite stack tries again, finds the second, and thus suceeds.
Imporant notes: I can't find anyone else with a field report of NEXT CHAIN working in the gLite stack. This is such a field report. It doesn't appear to work with ARC.
The fundamental problem is around the catchy titled OID 1.2.840.113549.1.9.1
No, wait, let me take a step back. On the Grid, we use certificates for authentication. An X509 certificate is, as with most certificates, a signed set of assertions, and a public key. As with the rest of the X500 standards, it's native language is something called ASN.1 (Abstract Syntax Notation 1) (aka X208, and the later revision X680), held in files encoded by the DER (Distinguished Encoding Rules).
The fundamental takeaway from that tech-dump is that X509 certificates are not in plain text, and there are multiple standards required in order to understand their contents.
So when someone says their certificate Distinguished Name is '/O=SomeUni/OU=SomeDept/L=group/CN=JohnSmith' ... that's not quite accurate. What they really mean is that there certificate DN is some set of objects that can be unambiguously matched to that ASCII text.
That happens because there are universally agreed mappings between the actually stored OID and the text representation of them (e.g. CN is OID 2.5.4.3).
Unfortunately, the agreement breaks down a bit for the emailAddress field; with some software mapping it to Email, and others to emailAddress. By the PKCS#9 standard, one could argue that it should be emailAddress - but that doesn't help us get software working.
Fortunatly, all of this is not a problem unless we want to store certificate DN's in ASCII, _and_ want to have email addresses in the DN.
Yeah, you can see where this is going, can't you?
In the UK, Jens has been working to allow us to not have them in DN's. However, in the short term, they are present.
One particular case where ASCII representations of the DN are used is in LSC files - which are used to authenticate VOMS servers. What happens is if the VOMS server DN matches the DN in the LSC file, and the cert was signed by the CA DN in the LSC file, _and_ the certificate chain is signed by a trusted root, then it's valid. This process means that we don't need to distribute lots of VOMS server certs, just the root CA's, and a small note (that shouldn't change over renewals) of the server DN.
I've been tidying up our ARC install here, and during the process managed to break things. Not unusual for me, (one of the reasons I avoid tiding at all costs!), but this one was quirky. I'd put the vomsdir under CFEngine control, so that it was sync'd with all the other servers, and suddenly it stopped accepting the scotgrid VO.
Root cause, as if you can't guess by now, LSC file, and the emailAddress. Looks like the gLite stack expects it one way, and ARC the other. Of course, by the time you read this, that's probably been fixed somewhere, but not in the version we had installed.
It turns out that there's one trick in LSC files that saves this case. Let me put the LSC file in here:
/C=UK/O=eScience/OU=Glasgow/L=Compserv/CN=svr029.gla.scotgrid.ac.uk/Email=grid-certificate@physics.gla.ac.uk
/C=UK/O=eScienceCA/OU=Authority/CN=UK e-Science CA
------ NEXT CHAIN ------
/C=UK/O=eScience/OU=Glasgow/L=Compserv/CN=svr029.gla.scotgrid.ac.uk/emailAddress=grid-certificate@physics.gla.ac.uk
/C=UK/O=eScienceCA/OU=Authority/CN=UK e-Science CA
The 'NEXT CHAIN' line lets one put multiple entries in the file. However, it appears that ARC isn't reading multiple, only the first one. So, in this case, I put the ARC friendly one first, so it matches fine - and the gLite stack tries again, finds the second, and thus suceeds.
Imporant notes: I can't find anyone else with a field report of NEXT CHAIN working in the gLite stack. This is such a field report. It doesn't appear to work with ARC.
Wednesday, December 21, 2011
Batch system juggling
We've been a bit quiet up here recently. This is normally a sign of either nothing interesting happening, or entirely too many interesting things happening. Opinions on that may divide, but I think it's closer to the latter...
One of the recent bits of fun that occurred was with our batch server. This story actually starts a long time ago; about this time last year. At that point, we started to get intermittent memory errors from the Torque server - corrected by ECC - but that's generally a sign that the RAM's about to fail. Given that the batch server is single point of failure for a site, that's not a good thing.
So I spent some time preparing a spare box, and being ready to move the batch system over, in case it failed over the winter break. Which, after all that prep, it didn't, and the errors stopped. On the expectation that the current hardware was nearing end of life, we ordered a new box early this year, and have had it sitting in a machine room for a while.
Unfortunately we didn't get time to have it running a tested batch system until our power supply started to ... well, insert colourful metaphor here, describing the 8 months where we were affected by lack of power.
Power got to stable supply in September, and so to catch up on things. One of the things we got around to was software versions. Whilst we didn't intent to update the Torque version, and managed to avoid it for a bit, the gLite developers eventually managed to sneak the update past us as part of an ordinary gLite update. Strictly, this didn't affect the batch server, just all the CE's, making them incompatible with the previous version of Torque.
Whilst a clever manoeuvre, reminiscent of Odysseus' Pony, it did leave us with a conundrum of either reverting the gLite update, or running forward with it. Neither were options of good character, but running forward did have some actual documentation; hence it was full speed ahead.
Which worked out well enough. The Torque 2.5.7 packages were set to use Munge, so getting that installed and tested as a first step helped it go smoothly. To preserve compatability in file locations, we used /etc/sysconfig/pbs_mom to put the pbs working directories in the same place as previously - meaning we didn't have to reconfigure any other tools.
What didn't go so smoothly was the memory leak in the server.
Which gave it a runtime of around 36 hours between crashes. Actually, not even crashes - we found that the pbs_server process hit either
or
and then sat around moaning. Had it crashed hard, then the auto-restart would have caught it. Ho, hum, one for the Fast Fail philosophy there.
By this point, my proof reader is pointing out that I started off talking hardware, and now talking software. Punchline is that the new server that we never got a chance to use has a lot more RAM than the old server. Therefore we wanted to move the server from the old hardware to the new, to give it a lot more RAM space. That won't fix the memory leak, but will mitigate the problem a bit.
Conventionally, this would involve draining the cluster, repositioning the CE's and then starting up everything again. Had we done that, this blog post would be over now.
Instead, we did a rolling update. This let us move things over without having to do a full drain. The biggest problem with a full drain is that, while most of the jobs finish within a shorter period of time that then limit, there are always some that take the full duration. This leaves us with an empty cluster, doing nothing, for 24 hours or so, wainting on a couple of jobs to finish.
So, instead, by moving things in small batches, then we can keep most of the nodes working, and thus get more work out of things. Step zero is to disable cfengine, otherwise it tends to try and 'fix' things part way through.
Step one is to drain a CE, which we did over a weekend, and a small number of nodes, which we put offline on the Sunday morning.
Come Monday, I set up and tested basic operations with the new batch server, and then moved the freed up nodes across to it. Once those were tested (which shook out a couple of issues about versioning of some libs), point the CE at the new batch server, and then run a test job though it. (It turns out that Atlas are fast enough to sneak some pilots through a 2 minute window for a test job. However, only a few, so they actually functioned as effective tests, without compromising the site if they failed).
After that, it's time to offline another CE, and then some more nodes, and start moving nodes over when they were empty. In the end I scripted this:
In theory one can run qmgr remotely, rather than ssh-ing to the batch servers and running a script. In practice, with the different versions of Torque, I couldn't get that to work. Note the automation of the mom config switch as well; and that this script checks that the node is empty.
This reduced the gradual move of nodes to a process of croning the script, and offlining nodes occasionally.
The net result was that we were operating at around 80% capacity for 48 hours, and it was all rather uneventful - in a good way. The final step was to update cfengine config and re-enable it.
One of the plus points of the above script is that it should be simple to adapt to two distinct batch systems; which means if we end up moving away from Torque, we should be able to do that without downtime too.
One of the recent bits of fun that occurred was with our batch server. This story actually starts a long time ago; about this time last year. At that point, we started to get intermittent memory errors from the Torque server - corrected by ECC - but that's generally a sign that the RAM's about to fail. Given that the batch server is single point of failure for a site, that's not a good thing.
So I spent some time preparing a spare box, and being ready to move the batch system over, in case it failed over the winter break. Which, after all that prep, it didn't, and the errors stopped. On the expectation that the current hardware was nearing end of life, we ordered a new box early this year, and have had it sitting in a machine room for a while.
Unfortunately we didn't get time to have it running a tested batch system until our power supply started to ... well, insert colourful metaphor here, describing the 8 months where we were affected by lack of power.
Power got to stable supply in September, and so to catch up on things. One of the things we got around to was software versions. Whilst we didn't intent to update the Torque version, and managed to avoid it for a bit, the gLite developers eventually managed to sneak the update past us as part of an ordinary gLite update. Strictly, this didn't affect the batch server, just all the CE's, making them incompatible with the previous version of Torque.
Whilst a clever manoeuvre, reminiscent of Odysseus' Pony, it did leave us with a conundrum of either reverting the gLite update, or running forward with it. Neither were options of good character, but running forward did have some actual documentation; hence it was full speed ahead.
Which worked out well enough. The Torque 2.5.7 packages were set to use Munge, so getting that installed and tested as a first step helped it go smoothly. To preserve compatability in file locations, we used /etc/sysconfig/pbs_mom to put the pbs working directories in the same place as previously - meaning we didn't have to reconfigure any other tools.
What didn't go so smoothly was the memory leak in the server.
Which gave it a runtime of around 36 hours between crashes. Actually, not even crashes - we found that the pbs_server process hit either
12/05/2011 10:19:12;0080;PBS_Server;Req;req_reject;Reject reply code=15012(PBS_Server System error: No child processes MSG=could not unmunge credentials), aux=0, type=AlternateUserAuthentication, from tomcat@svr021.gla.scotgrid.ac.uk
or
10/29/2011 18:11:24;0001;PBS_Server;Svr;PBS_Server;LOG_ERROR::Cannot allocate memory (12) in send_job, fork failed
and then sat around moaning. Had it crashed hard, then the auto-restart would have caught it. Ho, hum, one for the Fast Fail philosophy there.
By this point, my proof reader is pointing out that I started off talking hardware, and now talking software. Punchline is that the new server that we never got a chance to use has a lot more RAM than the old server. Therefore we wanted to move the server from the old hardware to the new, to give it a lot more RAM space. That won't fix the memory leak, but will mitigate the problem a bit.
Conventionally, this would involve draining the cluster, repositioning the CE's and then starting up everything again. Had we done that, this blog post would be over now.
Instead, we did a rolling update. This let us move things over without having to do a full drain. The biggest problem with a full drain is that, while most of the jobs finish within a shorter period of time that then limit, there are always some that take the full duration. This leaves us with an empty cluster, doing nothing, for 24 hours or so, wainting on a couple of jobs to finish.
So, instead, by moving things in small batches, then we can keep most of the nodes working, and thus get more work out of things. Step zero is to disable cfengine, otherwise it tends to try and 'fix' things part way through.
Step one is to drain a CE, which we did over a weekend, and a small number of nodes, which we put offline on the Sunday morning.
Come Monday, I set up and tested basic operations with the new batch server, and then moved the freed up nodes across to it. Once those were tested (which shook out a couple of issues about versioning of some libs), point the CE at the new batch server, and then run a test job though it. (It turns out that Atlas are fast enough to sneak some pilots through a 2 minute window for a test job. However, only a few, so they actually functioned as effective tests, without compromising the site if they failed).
After that, it's time to offline another CE, and then some more nodes, and start moving nodes over when they were empty. In the end I scripted this:
#!/bin/sh
NODE=$1
RUNNING=$(qstat -n -1 | grep $NODE | wc --lines)
if [ "x${RUNNING}" != "x0" ]
then
echo $NODE: Still $RUNNING jobs going, skipping
exit 2
fi
CORES=$(qmgr -c "print node ${NODE}" | grep "np = " | cut -d= -f2)
FROM=svr666
TO=svr999
echo $NODE: Moving to ${TO} with ${CORES} cores
ssh ${TO} "~/addNode.sh ${NODE} ${CORES}"
ssh ${NODE} "service pbs_mom stop"
scp config.mom.svr666 ${NODE}:/var/spool/pbs/mom_priv/config
ssh ${NODE} "service pbs_mom start"
ssh ${FROM} "~/deleteNode.sh ${NODE}"
In theory one can run qmgr remotely, rather than ssh-ing to the batch servers and running a script. In practice, with the different versions of Torque, I couldn't get that to work. Note the automation of the mom config switch as well; and that this script checks that the node is empty.
This reduced the gradual move of nodes to a process of croning the script, and offlining nodes occasionally.
The net result was that we were operating at around 80% capacity for 48 hours, and it was all rather uneventful - in a good way. The final step was to update cfengine config and re-enable it.
One of the plus points of the above script is that it should be simple to adapt to two distinct batch systems; which means if we end up moving away from Torque, we should be able to do that without downtime too.
Friday, September 23, 2011
Leaving Lyon
The EGI Tech Forum is winding down, with only a few talks remaining. It's been a great meeting, with a wide range of talks on all areas of Grid Computing. Lots to think about and new ideas to try out!
Wednesday, September 21, 2011
Scotgrid goes South
Last we week attended the bi-annual GridPP Collaboration meeting.
The venue this time was CERN itself and the meeting was, as ever, incredibly useful.
We were lucky enough to have presentations from the Experiments, the LHC, EGI and the WLCG community as well as presentations from across the UK collaboration.
A full programme of the meeting is available here:
http://www.gridpp.ac.uk/gridpp27/
Above is a picture of our own Dr Crooks presenting on the Glasgow Security Model
The venue this time was CERN itself and the meeting was, as ever, incredibly useful.
We were lucky enough to have presentations from the Experiments, the LHC, EGI and the WLCG community as well as presentations from across the UK collaboration.
A full programme of the meeting is available here:
http://www.gridpp.ac.uk/gridpp27/
Above is a picture of our own Dr Crooks presenting on the Glasgow Security Model
Monday, September 19, 2011
EGI Tech Forum 2011
Bonjour Lyon!After last week's GridPP 27 meeting in CERN, this week we are in Lyon for the 2011 EGI Tech Forum, running from Monday until Friday this week. You can follow the Forum online using some of the links here.
More later - time now to find some coffee before the first session...
Thursday, August 25, 2011
Busy Disks
After checking a test 10 gig Disk Server deployment we uncovered an interesting pattern in storage network activity and how our 10 Gig switch copes with multiply connections at 10 Gigabit. The captures below were taken over a 5 minute window of operation and show just how bursty the traffic patterns from these devices can be.
The graphs show all interfaces on our Dell 8024F and the measurement window is in Mbps. The order is top to bottom with the initial capture at the top.
While the Disk servers have been hammering away the round trip time intra room has been on average 0.40 msec between devices as the CPU on the core Dell seems more than happy to be handle these loads as its utilisation is approximately 20% presently.
We are planning to enable QOS metrics on disk server traffic shortly to test the response times on QOS and Non-QOS disk servers.
The graphs show all interfaces on our Dell 8024F and the measurement window is in Mbps. The order is top to bottom with the initial capture at the top.
We are planning to enable QOS metrics on disk server traffic shortly to test the response times on QOS and Non-QOS disk servers.
News Flash from ScotGrid Labs
In my last post, we investigating deployments of IPv6 on the test Cluster, the 1st one of which was using SLAAC to assign addressing to hosts. Interestingly enough it worked, first time out the tin.
An IPv6 Traceroute from the web is shown below:
traceroute to 2001:630:40:ef0:230:48ff:fe5a:4b7 (2001:630:40:ef0:230:48ff:fe5a:4b7), 30 hops max, 40 byte packets
1 2001:1af8:4200:b000::1 (2001:1af8:4200:b000::1) 1.600 ms 1.813 ms 1.882 ms
2 2001:1af8:4100::5 (2001:1af8:4100::5) 1.320 ms 1.392 ms 1.465 ms
3 be11.crs.evo.leaseweb.net (2001:1af8::9) 2.587 ms 2.631 ms 2.619 ms
4 linx-gw1.ja.net (2001:7f8:4::312:1) 8.475 ms 8.466 ms 8.453 ms
5 ae1.lond-sbr4.ja.net (2001:630:0:10::151) 78.338 ms 78.388 ms 78.376 ms
6 2001:630:0:10::109 (2001:630:0:10::109) 9.900 ms 9.479 ms 9.446 ms
7 so-5-0-0.warr-sbr1.ja.net (2001:630:0:10::36) 13.320 ms 13.196 ms 13.317 ms
8 2001:630:0:10::296 (2001:630:0:10::296) 18.705 ms 18.542 ms 18.793 ms
9 clydenet.glas-sbr1.ja.net (2001:630:0:8044::206) 18.947 ms 18.931 ms 18.948 ms
10 2001:630:42:0:3e::9a (2001:630:42:0:3e::9a) 19.434 ms !X 18.214 ms !X 17.682 ms !X
The next phase of testing will be to enable a webserver to speak in both IPv4 and IPv6 using this access mechanism and then onto a Grid services .
I will post up a more detailed explanation of the mechanisms used for this soon.
An IPv6 Traceroute from the web is shown below:
traceroute to 2001:630:40:ef0:230:48ff:fe5a:4b7 (2001:630:40:ef0:230:48ff:fe5a:4b7), 30 hops max, 40 byte packets
1 2001:1af8:4200:b000::1 (2001:1af8:4200:b000::1) 1.600 ms 1.813 ms 1.882 ms
2 2001:1af8:4100::5 (2001:1af8:4100::5) 1.320 ms 1.392 ms 1.465 ms
3 be11.crs.evo.leaseweb.net (2001:1af8::9) 2.587 ms 2.631 ms 2.619 ms
4 linx-gw1.ja.net (2001:7f8:4::312:1) 8.475 ms 8.466 ms 8.453 ms
5 ae1.lond-sbr4.ja.net (2001:630:0:10::151) 78.338 ms 78.388 ms 78.376 ms
6 2001:630:0:10::109 (2001:630:0:10::109) 9.900 ms 9.479 ms 9.446 ms
7 so-5-0-0.warr-sbr1.ja.net (2001:630:0:10::36) 13.320 ms 13.196 ms 13.317 ms
8 2001:630:0:10::296 (2001:630:0:10::296) 18.705 ms 18.542 ms 18.793 ms
9 clydenet.glas-sbr1.ja.net (2001:630:0:8044::206) 18.947 ms 18.931 ms 18.948 ms
10 2001:630:42:0:3e::9a (2001:630:42:0:3e::9a) 19.434 ms !X 18.214 ms !X 17.682 ms !X
The next phase of testing will be to enable a webserver to speak in both IPv4 and IPv6 using this access mechanism and then onto a Grid services .
I will post up a more detailed explanation of the mechanisms used for this soon.
Tuesday, August 23, 2011
Two Stacks are better than one
Leading on from the last post, we have also re-introduced a new test cluster. This infrastructure is housed within the same rack as our old worker nodes but is completely independent of the production cluster. Supporting a Dell 8024F are 5 servers and a Dell 5000 series switch which are connected via an independent 1 gigabit fibre connection to the University's network.
The purpose of this cluster is to test IPv4/IPv6 dual stack connectivity for grid Services, the testing of switch based security mechanisms and SL6 NAT testing without fear of impacting the real cluster.
The IPv6 connectivity model testing will be in multiple phases which include:
* SLAAC
* IPv6 to IPv4 tunneling
* IPv6 Routing
This framework is designed to comply with the HEPIX IPv6 Project and to look at the possible connection models required by Tier-2s to utilise IPv6. Additionally, we will be testing a wide variety of Grid enabled applications and associated systems such as Nagios to investigate potential issues within a dual stack deployment.
More on this soon.
The purpose of this cluster is to test IPv4/IPv6 dual stack connectivity for grid Services, the testing of switch based security mechanisms and SL6 NAT testing without fear of impacting the real cluster.
The IPv6 connectivity model testing will be in multiple phases which include:
* SLAAC
* IPv6 to IPv4 tunneling
* IPv6 Routing
This framework is designed to comply with the HEPIX IPv6 Project and to look at the possible connection models required by Tier-2s to utilise IPv6. Additionally, we will be testing a wide variety of Grid enabled applications and associated systems such as Nagios to investigate potential issues within a dual stack deployment.
Night of the Return of the Living Worker Nodes
As Glasgow is currently being used as one of the sets for World War Z, we thought it only apt that we too resurrect the dead and get them to do our bidding. No, we haven't embraced "mad" science.
During the power work we decided to alter the layout of 243d. Historically, the room had housed a mainframe including operators booths. One of these booths still existed within 243d, so we took down one of the walls and added a new cabinet.
While the work was being conducted to remove the wall we covered the cluster and powered it off to minimise dust ingestion. If you wish to gift wrap a cluster we have plenty of experience in this field. However, our wrapping is limited to blue plastic presently.
After the wall had been removed, we cleared out the computer room and re-organised the storage cabinets, cabling and computing cabinets. In 243d there were a pile of 6 year old disused worker nodes and racked worker nodes whose PDU had been damaged during one of our many power cuts over the last 12 months. In addition to this we found and rebuilt a Dell Rack and also we had a spare Nortel 5510 switch.
With the newly available space from the removal of the wall in 243d, we got a tile cut and deployed the rack. The rack connects back to the older Stack01 via a copper gigabit Ethernet connection. This deployment will give us up to approximately 100 job slots once they are fully configured.
While the work was being conducted to remove the wall we covered the cluster and powered it off to minimise dust ingestion. If you wish to gift wrap a cluster we have plenty of experience in this field. However, our wrapping is limited to blue plastic presently.
After the wall had been removed, we cleared out the computer room and re-organised the storage cabinets, cabling and computing cabinets. In 243d there were a pile of 6 year old disused worker nodes and racked worker nodes whose PDU had been damaged during one of our many power cuts over the last 12 months. In addition to this we found and rebuilt a Dell Rack and also we had a spare Nortel 5510 switch.
With the newly available space from the removal of the wall in 243d, we got a tile cut and deployed the rack. The rack connects back to the older Stack01 via a copper gigabit Ethernet connection. This deployment will give us up to approximately 100 job slots once they are fully configured.
Friday, August 12, 2011
Running at capacity again
... after the shutdown. Slightly delayed due to a coming back during a low point in Atlas work, which is now past us.
Here's a graph of data moved from our storage element, and you can probably pick out the rather subtle peak when the last batch of analysis traffic started (taking us up to capacity):
Wednesday, August 10, 2011
Power startup, situation (hopefully) normal
The planned power work in the Kelvin Building was completed this morning and we have been transferred back to our proper power feed from the generators. The power startup went smoothly and the building has returned to normal.
The Scotgrid cluster was restarted after the power was seen to be stable and we came out of downtime at 2.20 pm. We will monitor our situation, but we hope that this power work will improve our stability over the coming months.
The Scotgrid cluster was restarted after the power was seen to be stable and we came out of downtime at 2.20 pm. We will monitor our situation, but we hope that this power work will improve our stability over the coming months.
Wednesday, August 03, 2011
Controlled Shut Down. Please standby.
As many regular readers of our blog may have noticed, we have had several power cuts over the last 8 months. While the Scot Grid Glasgow cluster has survived relatively well with these interruptions, the School of Physics and Astronomy at the University of Glasgow has under taken a piece of work to resolve this re-current issue.
Therefore, on the 7th - 10th of August we will be going into a controlled downtime period so that the transformers which supply the mains feed into our site can be removed and upgraded.
We should be back in action on the morning of Wednesday the 10th.
Therefore, on the 7th - 10th of August we will be going into a controlled downtime period so that the transformers which supply the mains feed into our site can be removed and upgraded.
We should be back in action on the morning of Wednesday the 10th.
Thursday, July 28, 2011
Circuits, Circuits everywhere but not a drop to switch
Since the late afternoon of the 26th of July we have been working to resume service on the Cluster at Glasgow.
We were put into unexpected downtime by our old friend; the power cut.
The root cause of this appears to be that the local mains supply into the site failed and was sub-sequentially re-instated. However, we decided to restart the cluster on Wednesday morning, to ensure that there was a clean and stable supply into the site. So off to the Gocdb, announce the unscheduled downtime and proceed.
While normally we would have immediately started on getting the cluster back online, as it turned out we couldn't have got ourselves back into production any sooner due to the residual issues caused by the power outage. As we have had several power interruptions at the site over the last 10 months, we have now got a reasonably robust restart procedure and we started this on Wednesday morning.
Initially, we had absolutely no issues surrounding the reset of both rooms, bar the loss of a rather expensive 10 Gig Ethernet interface on one of the new Dell Switches and the loss of the switch configuration files, which was caused by yours truly not running a copy run start on the switch after configuring a LAG group and QOS. We reconfigured the switch and all connectivity across the cluster was confirmed as good.
We then proceeded to rebuild our one of our internal stacks to free up the 10 Gig Interfaces on a Nortel 5530, which we had planned to move to our lower server room to build out the second 10 Gig link, mentioned in a previous post. This too went surprisingly well, but Dave and myself had pretested building the stack and adding and removing devices and inserting new base units on older test equipment.
We then retested again Stacking, LAGs were working fine, Spanning tree was happy and the Cluster's network was in good shape. We then moved to phase 2 of the upgrade which was to insert the 5530 switch into the switch stack in the downstairs server room. After we inserted the switch in the stack, it came up and the entire stack stabilised and then started to forward traffic.
However, about 3 minutes later we started to see the latency in the network rise and hosts fail to contact one another. Ping, SSH and normal cluster network traffic such as NFS, NTP and DNS also started to experience issues. We reduced the load on the network by detaching hosts from it but to no avail. We then removed the 5530 from the stack but the problem remained. Over the next 4 hours we tried a variety of tests which were all ending with either the dreaded Host Unreachable or 142 millisecond response times. To make matters worse (confusing), the switches were reporting an internal response time between room of 0.50 milliseconds via ping but telnet and ssh between devices was also timing out.
As we were unable to ascertain the exact root cause, we called a break and went and got some air.
20 minutes and one pizza slice later, it occurred to me that if no device on the network was generating traffic at the volume required to generate a 94% packet loss scenario across multiple 10 Gig connections, then it has to be the network itself. Or rather what is attached to it.
The 10 Gig Interface being cooked wasn't the cause as it was dead at this point, but the power cut had left another present:
Damaged Ethernet Cables.
As the Cluster is too large to manually go round and check every cable individually with a line tester, we did something that I, as a former telco engineer, don't like doing. We rebooted the switches in numbered sequence. Starting with Stack01.
The purpose of this test is to isolate as quickly as possible the damaged cable, device or interface by pinging across the cluster from one room to another and intra switch if need be.
So Ping from Svr001 (upstairs) to Node141 (downstairs).
Destination Host Unreachable.
Leave the ping running.
Reboot Stack 01.
Ping response time of 0.056 miliseconds
Stack01 reloads.
Destination Host Unreachable.
We repeated this test twice. And got the same result.
So onto Stack01. The partner switch which trunks into this stack to affect an uplink onto the core of our network did not report any errors on the multi-link trunk but also very little traffic. Neither did Stack01, until I tried to ping its loopback address from the partner switch. The error rate on the interfaces increased and CRC counters were recorded. So we systematically disabled the multi-link trunk link by link until the stack interconnect stablised.
This reduced the trunk's capacity substantially but it also stabilised the network. So we added the 5530 back into the Stack downstairs, turned on the partner ports upstairs and were awarded with a 20 Gig backbone which is now operational at the Glasgow site.
As for the old LAG connection it was stripped out completely this morning and by early afternoon we had re-instated a 6 Gig connection to Stack01 which is working happily. From here we brought the site out of downtime and are back on the Grid.
We are putting in place an internal tftp process for backing up switch configurations each night.
The main lesson from this is that on a large layer 2 environment, the smallest issue can become a major one and plans are well advanced on the next set of configuration changes to the network at Glasgow, to get around this and other potential issues in the future.
We were put into unexpected downtime by our old friend; the power cut.
The root cause of this appears to be that the local mains supply into the site failed and was sub-sequentially re-instated. However, we decided to restart the cluster on Wednesday morning, to ensure that there was a clean and stable supply into the site. So off to the Gocdb, announce the unscheduled downtime and proceed.
While normally we would have immediately started on getting the cluster back online, as it turned out we couldn't have got ourselves back into production any sooner due to the residual issues caused by the power outage. As we have had several power interruptions at the site over the last 10 months, we have now got a reasonably robust restart procedure and we started this on Wednesday morning.
Initially, we had absolutely no issues surrounding the reset of both rooms, bar the loss of a rather expensive 10 Gig Ethernet interface on one of the new Dell Switches and the loss of the switch configuration files, which was caused by yours truly not running a copy run start on the switch after configuring a LAG group and QOS. We reconfigured the switch and all connectivity across the cluster was confirmed as good.
We then proceeded to rebuild our one of our internal stacks to free up the 10 Gig Interfaces on a Nortel 5530, which we had planned to move to our lower server room to build out the second 10 Gig link, mentioned in a previous post. This too went surprisingly well, but Dave and myself had pretested building the stack and adding and removing devices and inserting new base units on older test equipment.
We then retested again Stacking, LAGs were working fine, Spanning tree was happy and the Cluster's network was in good shape. We then moved to phase 2 of the upgrade which was to insert the 5530 switch into the switch stack in the downstairs server room. After we inserted the switch in the stack, it came up and the entire stack stabilised and then started to forward traffic.
However, about 3 minutes later we started to see the latency in the network rise and hosts fail to contact one another. Ping, SSH and normal cluster network traffic such as NFS, NTP and DNS also started to experience issues. We reduced the load on the network by detaching hosts from it but to no avail. We then removed the 5530 from the stack but the problem remained. Over the next 4 hours we tried a variety of tests which were all ending with either the dreaded Host Unreachable or 142 millisecond response times. To make matters worse (confusing), the switches were reporting an internal response time between room of 0.50 milliseconds via ping but telnet and ssh between devices was also timing out.
As we were unable to ascertain the exact root cause, we called a break and went and got some air.
20 minutes and one pizza slice later, it occurred to me that if no device on the network was generating traffic at the volume required to generate a 94% packet loss scenario across multiple 10 Gig connections, then it has to be the network itself. Or rather what is attached to it.
The 10 Gig Interface being cooked wasn't the cause as it was dead at this point, but the power cut had left another present:
Damaged Ethernet Cables.
As the Cluster is too large to manually go round and check every cable individually with a line tester, we did something that I, as a former telco engineer, don't like doing. We rebooted the switches in numbered sequence. Starting with Stack01.
The purpose of this test is to isolate as quickly as possible the damaged cable, device or interface by pinging across the cluster from one room to another and intra switch if need be.
So Ping from Svr001 (upstairs) to Node141 (downstairs).
Destination Host Unreachable.
Leave the ping running.
Reboot Stack 01.
Ping response time of 0.056 miliseconds
Stack01 reloads.
Destination Host Unreachable.
We repeated this test twice. And got the same result.
So onto Stack01. The partner switch which trunks into this stack to affect an uplink onto the core of our network did not report any errors on the multi-link trunk but also very little traffic. Neither did Stack01, until I tried to ping its loopback address from the partner switch. The error rate on the interfaces increased and CRC counters were recorded. So we systematically disabled the multi-link trunk link by link until the stack interconnect stablised.
This reduced the trunk's capacity substantially but it also stabilised the network. So we added the 5530 back into the Stack downstairs, turned on the partner ports upstairs and were awarded with a 20 Gig backbone which is now operational at the Glasgow site.
As for the old LAG connection it was stripped out completely this morning and by early afternoon we had re-instated a 6 Gig connection to Stack01 which is working happily. From here we brought the site out of downtime and are back on the Grid.
We are putting in place an internal tftp process for backing up switch configurations each night.
The main lesson from this is that on a large layer 2 environment, the smallest issue can become a major one and plans are well advanced on the next set of configuration changes to the network at Glasgow, to get around this and other potential issues in the future.
Thursday, July 14, 2011
We make knowledge possible
Just a quick Blog post in regards to the the WLCG workshop held at DESY in Hamburg from the 11th to 13th of July.
The various presentations covered aspects of all the experiments and the future requirements for systems, storage, monitoring and networks.
Links to the workshop agenda and content can be found here:
https://indico.cern.ch/conferenceDisplay.py?confId=124407
The various presentations covered aspects of all the experiments and the future requirements for systems, storage, monitoring and networks.
Links to the workshop agenda and content can be found here:
https://indico.cern.ch/conferenceDisplay.py?confId=124407
Monday, July 11, 2011
Everyone's doing a brand new filesystem now: Come on, baby, do the cvmfs now.
Ever since I heard about it at CHEP 2010, I've been itching to get CVMFS set up at Glasgow, because it was so clearly a better solution for software provision than the old sgm-role / NFS-mounted area approach.
In our case, I created the two config files, stuck them in the skel directories for worker nodes in cfengine, and added them to the list of files that are expected to be on worker nodes in the config.
5 ) You can check that all this is working by trying a service cvmfs probe
or explicitly mounting a cvmfs path somewhere outside of automount's config.
With the default config, atlas software is at /cvmfs/atlas.cern.ch and so on.
Concerns about the reliability of the hardware that the service was running on (it may still not be on production hardware at CERN as I write this) always held the more sensible minds here back, but now that it's all up and working at RAL, and RAL is providing a stratum-1 cache as a backup, there's nothing stopping us.
So, following a combination of Ian Collier's description of the set-up at RAL and the official CernVMFS technical report (pdf), with some adjustments to make changes to our Cfengine config, I spent some of last week getting cvmfs working on the cluster.
For your edification, this is what I did:
1) First, set up the new repository you need. In our case, yum repositories (and gpg keys) are managed by cfengine, so, in our cfengine skel directory for the worker nodes, I added:
wget http://cvmrepo.web.cern.ch/cvmrepo/yum/cernvm.repo -P ./skel/workers/etc/yum.repos.d/wget http://cvmrepo.web.cern.ch/cvmrepo/yum/RPM-GPG-KEY-CernVM -P ./skel/workers/etc/pki/rpm-gpg/
2) Fuse and cvmfs both want to have user and group entries created for them. We manage users and groups with cfengine, so I added a fuse group to /etc/groups and a cvmfs user and group. The cvmfs user also needs to be added as a member of the fuse group.
3) Now that the initial set-up bits are done, the new packages can be installed, again, using cfengine. I added the packages
fuse ; fuse-libs ; cvmfs ; cvmfs-keys ; cvmfs-init-scripts
to the default packages for our worker node class in cfengine.
4) Editing configuration files.
You need to edit auto.master to get autofs to support cvmfs.
(Just add a line like
/cvmfs /etc/auto.cvmfs
as the auto.cvmfs map is added by the cvmfs rpm.
Remember to issue a:
service autofs reload
afterwards, or get your configuration management system to do so automagically for you.
)
You also need to configure fuse to allow users to access things as other users:
/etc/fuse.conf
user_allow_otherAnd finally, you need to actually configure cvmfs itself. Cvmfs uses 2 main configuration files:
default.local, which specifies modifications of the default settings for the local install
cern.ch.local, which specifies modifications of the default server to use for *.cern.ch repositories.
/etc/cvmfs/default.local needs to be configured for:
CVMFS_USER=cvmfs
CVMFS_NFILES=32768
#CVMFS_DEBUGLOG=/tmp/cvmfs.log
CVMFS_REPOSITORIES=atlas.cern.ch,atlas-condb.cern.ch,lhcb.cern.ch,cms.cern.ch,geant4.cern.ch,sft.cern.ch
CVMFS_CACHE_BASE=/tmp/cache/cvmfs2/
CVMFS_QUOTA_LIMIT=10000
CVMFS_HTTP_PROXY="nameoflocalsquid1|nameoflocalsquid2"
/etc/cvmfs/cern.ch.local, for UK sites should probably be configured as:
CVMFS_SERVER_URL="http://cernvmfs.gridpp.rl.ac.uk/opt/@org@;http://cvmfs-stratum-one.cern.ch/opt/@org@"
(since RAL is closer to us than CERN).
A brief note: ';' in a list of options specifies failover, and '|' load-balancing. So "foo;bar" means "try foo, then bar", while "foo|bar;baz" means "try to load-balance queries between foo and bar, if that fails, try baz". This works for the squid proxy specifiers in default.local and also the server destinations in cern.ch.local .
Another note: the cache directory specified in default.local should be large enough to actually cache a useful amount of data on each worker node. 10Gb per VO is reported to be comfortably enough, for atlas and lhcb, and therefore is probably wildly exorbitant for any other VO that would be using it. I've tested, and you can happily set this directory to be readable only by the cvmfs user, which gives you a tiny bit more security.
If you change the configuration files for cvmfs, you need to get it to reload them, like autofs.
service cvmfs reload
seems to work fine (and our cfengine config now does this if it has to update those config files).
In our case, I created the two config files, stuck them in the skel directories for worker nodes in cfengine, and added them to the list of files that are expected to be on worker nodes in the config.
5 ) You can check that all this is working by trying a service cvmfs probe
or explicitly mounting a cvmfs path somewhere outside of automount's config.
With the default config, atlas software is at /cvmfs/atlas.cern.ch and so on.